Back to homePhysics · 6th Year OL · Change subject
Start for free
6th Year OL · Physics
Charge, Atomic Models, X-rays and Semiconductors · The Electron and X-rays

X-rays and the Photoelectric Effect

A hospital in Dublin takes a chest X-ray in a fraction of a second. In the same building, an automatic door opens as you walk up to it. Both depend on photons meeting electrons. In the door, light knocks electrons out of a metal. In the X-ray machine, fast electrons produce light of extremely high frequency. This page explains both, and why they are, in a sense, opposite processes.

Photons and the photoelectric effect

Shine light on a clean metal surface and, under the right conditions, electrons are emitted. This is photoelectric emission. The surprising part is which light works.

  • Ultraviolet light on zinc frees electrons, however dim it is.

  • Red light on the same zinc frees none, however bright it is.

There is a minimum frequency below which nothing happens.

The wave model of light cannot explain this. A wave spreads its energy over the surface, so a bright enough red beam should eventually give an electron enough energy to escape. It does not. The particle model does explain it: light arrives in packets called photons, and each photon has energy

$$E = hf$$

where $h = 6.63\times10^{-34}\ \text{J s}$ is Planck's constant and $f$ is the frequency. One photon gives all its energy to one electron, or none at all. The electron cannot save up energy from several weak photons.

If $hf$ is bigger than $\Phi$, the extra energy becomes kinetic energy of the electron. This is conservation of energy:

$$hf = \Phi + \tfrac{1}{2}mv^2_{max}$$

The electron has maximum kinetic energy when it comes from the surface. Electrons from deeper in the metal lose some energy on the way out.

Energies of electrons are very small in joules, so we often use the electronvolt: $1\ \text{eV} = 1.6\times10^{-19}\ \text{J}$.

Photons strike a metal surface and an electron leaves with kinetic energy equal to photon energy minus work function. Metal surface Photon, energy hf Electron, ½mv² max hf = Φ + ½mv² max

Stopping potential and finding h

How do we measure the maximum kinetic energy of the electrons? We make the collecting plate negative so that it repels them. The smallest p.d. that stops even the fastest electrons reaching it is the stopping potential, $V_s$. The electrons lose their kinetic energy doing work against the field, so

$$eV_s = \tfrac12mv^2_{max} = hf - \Phi$$

Rearranged as $V_s = \dfrac{h}{e}f - \dfrac{\Phi}{e}$, this is a straight line, $y = mx + c$.

Graph of stopping potential against frequency: a straight line that meets the frequency axis at the threshold frequency. Frequency f (Hz) Stopping potential Vs (V) f₀ slope = h/e
  • The line meets the frequency axis at $f_0$, the threshold frequency.

  • The slope is $\dfrac{h}{e}$, so $h = e\times\text{slope}$.

  • The line extended back to $f = 0$ meets the $V_s$ axis at $-\dfrac{\Phi}{e}$.

The slope is the same for every metal. Only $f_0$ changes, so different metals give parallel lines.

You can verify the photoelectric effect without a lab: take published $V_s$ and $f$ data for a metal from a secondary source (a textbook table or a university website), plot $V_s$ against $f$ and check that the points lie on a straight line. Then compare the slope $\times\, e$ with the accepted value of $h$.

Photocells

A photocell (photoelectric cell) uses the photoelectric effect. Light falls on a metal cathode inside an evacuated tube. Emitted electrons are collected by the anode, so a small current flows in the circuit. This current, the photocurrent, is proportional to the light intensity as long as $f > f_0$.

Uses of photocells:

  • automatic doors, which open when a beam is broken

  • burglar alarms and counters on a production line

  • light meters in cameras

  • reading the sound track on old cinema film

To trigger a door or alarm, the circuit detects the photocurrent dropping to zero when something blocks the beam.

Practice★☆☆Not started
Name two uses of X-rays in medicine or industry, and name one use of a photocell (photoelectric cell) such as an automatic door or a light meter.

Name two uses of X-rays in medicine or industry, and name one use of a photocell (photoelectric cell) such as an automatic door or a light meter.

Solve
Practice★★☆Not started
A photocell is used in a burglar alarm. A light beam falls on the cathode and a photocurrent flows. a) Explain how the alarm is triggered when the beam is interrupted.…

A photocell is used in a burglar alarm. A light beam falls on the cathode and a photocurrent flows.

  1. a) Explain how the alarm is triggered when the beam is interrupted.
  2. b) State what happens to the photocurrent if the intensity is doubled at constant frequency.
  3. c) State what happens if the frequency is below the threshold frequency, no matter how intense.
Solve

Producing X-rays

X-rays are electromagnetic radiation with very high frequency (wavelengths of about $10^{-11}$ to $10^{-9}\ \text{m}$). They are produced when fast electrons are stopped by a metal target.

In an X-ray tube:

  1. A heated filament (the cathode) emits electrons by thermionic emission.

  2. A very high p.d. (tens of kV) accelerates the electrons towards the metal target (the anode), in a vacuum.

  3. The electrons strike the target and are rapidly stopped.

An X-ray tube: electrons from a hot cathode are accelerated by a high voltage to a metal target, which emits X-rays. Hot cathode Target (anode) Electrons X-rays High voltage, tens of kV

Energy transformation at the target. The kinetic energy of the electrons becomes:

  • X-ray photons (only about 1%)

  • heat (about 99%)

This is why the target is made of a metal with a high melting point (such as tungsten) and is cooled. Modern machines use a rotating anode, so the electron beam strikes a different part of the target all the time and the heat is spread over a larger area.

Maximum photon energy. An electron accelerated through a p.d. $V$ gains kinetic energy $eV$. The most energetic photon is made when an electron gives all of its energy to one photon:

$$eV = hf_{max} = \frac{hc}{\lambda_{min}}$$

So a higher accelerating voltage gives a higher maximum frequency and a shorter minimum wavelength, which means more penetrating X-rays.

The X-ray spectrum

If we plot intensity against wavelength we see two features:

X-ray spectrum: a continuous background beginning at a sharp minimum wavelength, with two tall narrow peaks. Wavelength λ Intensity λ min Characteristic peaks Continuous
  • A sharp cut-off at $\lambda_{min}$. No photon can have more energy than the electron that made it, $eV$. So there is a shortest wavelength, set only by the voltage.

  • A continuous background. Electrons slow down in many stages, in collisions of different strength, so photons have all energies up to the maximum.

  • Sharp peaks. An incoming electron can knock an inner electron out of a target atom. When an outer electron drops into the gap, it emits a photon of a definite energy. These peaks depend on the target metal, not on the voltage.

Uses of X-rays. In medicine: imaging bones (X-ray radiographs) and CT scans, and radiotherapy for cancer. In industry: checking welds and cracks in metal, and airport security scanners. X-rays are ionising, so exposure is kept as low as possible.

Practice★☆☆Not started
a) Describe how X-rays are produced in an X-ray tube. b) What is the energy transformation at the target? c) Why is the target cooled?
  1. a) Describe how X-rays are produced in an X-ray tube.
  2. b) What is the energy transformation at the target?
  3. c) Why is the target cooled?
Solve
Practice★★☆Not started
An X-ray tube in a Dublin hospital operates at $60\ \text{kV}$. Use $h=6.63\times10^{-34}\ \text{J s}$, $e=1.6\times10^{-19}\ \text{C}$ and…

An X-ray tube in a Dublin hospital operates at $60\ \text{kV}$. Use $h=6.63\times10^{-34}\ \text{J s}$, $e=1.6\times10^{-19}\ \text{C}$ and $c=3.0\times10^{8}\ \text{m s}^{-1}$.

  1. a) Calculate the maximum energy of an X-ray photon produced.
  2. b) Calculate the corresponding maximum frequency.
  3. c) Calculate the minimum wavelength.
Solve
Practice★★★Not started
An X-ray tube operates at $80\ \text{kV}$ with a beam current of $10\ \text{mA}$. Only $1.0\%$ of the electron beam power is converted to X-rays. a) Calculate the power…

An X-ray tube operates at $80\ \text{kV}$ with a beam current of $10\ \text{mA}$. Only $1.0\%$ of the electron beam power is converted to X-rays.

  1. a) Calculate the power of the electron beam.
  2. b) Calculate the power converted to heat.
  3. c) Calculate the minimum wavelength of the X-rays.
  4. d) Explain, with reference to the heat, the design of the rotating anode in modern X-ray machines.
Solve

Two inverse processes

The two effects mirror each other:

Photoelectric effect X-ray production
Input photons electrons
Output electrons photons
Energy relation $hf = \Phi + \tfrac12mv^2_{max}$ $eV = hf_{max}$
Typical energies a few eV tens of keV

In the photoelectric effect a photon's energy is turned into an electron's kinetic energy (after paying $\Phi$). In an X-ray tube the electron's kinetic energy is turned back into a photon. Both are explained only by the particle model of light, where energy is exchanged in whole photons of $hf$. The work function is negligible for X-rays, because $eV$ is thousands of times bigger.

Practice★★★Not started
Compare the X-ray tube and the photoelectric effect as inverse processes. a) Explain in what sense they are "inverse" in terms of energy conversion between photons and…

Compare the X-ray tube and the photoelectric effect as inverse processes.

  1. a) Explain in what sense they are "inverse" in terms of energy conversion between photons and electrons.
  2. b) In an X-ray tube, electrons accelerated through $40\ \text{kV}$ strike a target. Calculate the shortest wavelength produced.
  3. c) Explain why the X-ray spectrum has a sharp cut-off wavelength and discrete peaks superimposed on a continuous background.
  4. d) Explain why the photoelectric effect cannot be explained by the wave model of light.
Solve

Summary

  • Light comes in photons of energy $E = hf$. One photon frees at most one electron.

  • The work function is $\Phi = hf_0$. Photoelectric emission follows $hf = \Phi + \tfrac12mv^2_{max}$.

  • Frequency controls the electrons' maximum kinetic energy, and intensity controls how many are emitted. Below $f_0$ nothing is emitted. The wave model cannot explain this.

  • $eV_s = hf - \Phi$. A $V_s$ against $f$ graph has slope $h/e$ and meets the frequency axis at $f_0$.

  • A photocell turns light into a photocurrent, which is useful in alarms, doors and light meters.

  • In an X-ray tube, $eV = hf_{max} = hc/\lambda_{min}$. About 1% of the beam power becomes X-rays and the rest is heat, so the target is cooled.

  • The X-ray spectrum has a continuous background, a sharp cut-off $\lambda_{min}$ and characteristic peaks.

See all the exercises in this section